Description

The Air Shower Interlocking System ensure that out of the N Number of doors locked by an Interlocking controller, only one door at a time will open and other doors remain closed even if a request is placed to open any one of them. This effectively warrants air passing through and minimizes microbiological and particulate contamination of the air locked area and assists in sterilization of person passing through the Air shower.

Our Range of Air Shower Interlocking Systems

In our range of Air shower interlocking Systems we offer 2 &3 Doors controllers, available in both Vertical & Horizontal Displays with One side / all sides Blower operation (Programmable at site).

Air Shower Controller in India
Air Shower Controller in India

FEATURES*

  1. Industrial & Aesthetically designed I.C. based Controller.
  2. Mother & Host PCB Design: In case malfunctioning, entire Interlocking Controller can be replaced within 5 seconds by supplanting a new PCB without using any tools, or touching any wires.
  3. Fully programmable time interval for lock opening.
  4. One side / Both sides Blower operation programmable at site.
  5. Clearly marked connections on the PCB.
  6. Display Panel with Switch & Clear door status indications:(if any the other doors is open). This helps elimination confusion in the users mind and hence eliminates needless fiddling with the doors.
  7. Soft touch key on the Display Panel.
  8. Manual override buttons to control LIGHT & FAN clearly indicating their function status On/Off & Auto/Mannual.
  9. Emergency Switch - Button to override the interlocking system & unlock all the doors at the same time in case of emergency such as fire, gas leak etc.
  10. Buzzer sound on the emergency switch.
  11. Access Control Integration for authorized only entry.
  12. Light & Air Curtain Integration.
  13. Fire Alarm Integration.
  14. Emergency Siren Integration.
  15. Extra Auxiliary Output.
  16. Door open Alert.

WORKING :

  1. At the default stage all doors connected to the Air Shower Controller are closed & locked. The Display switches on all the doors indicate the status as ("LOCKED"). The Light & Blower are off (on auto mode).
  2. The user approaches the door and presses the REX Switch (Press to Open). The indicator status on that particular door changes to Go and the door is unlocked for the user to place the product inside the pass box. Simultaneously:
    1. The indicator status on all other doors changes to WAIT.
    2. The Light (inside) is turned ON.
    3. The LIGHT indication on the Display turns on in green colour (Auto).
  3. During this process a request placed by any other user on any other door indicating WAIT will be declined.
  4. Once the door is closed by the user upon entering the Air Shower enclosure.
    1. The FAN (Blower) is turned ON.
    2. The FAN indication on the Display turns ON in green colour (Auto)
    3. All Doors get locked & Fan (Blower) is on for the duration of 20-30 seconds (time programmable at site).
    4. Countdown will begin in the Display Panel at the door.
  5. After the programed time lapses, the exit door will get unlocked for 5-10 seconds, for the user to open and exit.
  6. Once the exit door is closed, the cycle will be considered complete and Air shower controller will come back to Default State wherein :
    1. The FAN & CFL will be switched off.
    2. All doors get locked.
  7. Status Indicators on all doors change to ("LOCKED")

AIR SHOWER CONTROLLER PROGRAMMING:

  1. For one side blower operation:
    1. Keep down arrow switch on the Display Panel 1, pressed for 10 seconds.
    2. The display will show and flash “A1”. This means the FAN will work only while entering from Door 1.
  2. For Both side blower operation:
    1. Keep up arrow switch on the Display Panel 1, pressed for 10 seconds.
    2. The display will show and flash “A2”. This means the FAN will work while entering from both Doors.
  3. For Setting the timing of Fan:
    1. Keep   Both arrow switches on the Display pressed simultaneously for 10 seconds.
    2. The display will show programmed time and will keep on flashing.
    3. Press Down arrow or up arrow to decrease or increase the timing to desired level.

Air Shower Interlocking Manufacturers in India

ALLSECURE ENTERPRISES stands as a leading name among Air Shower Interlocking manufacturers in India. Our innovative Air Shower Interlocking System ensures that out of the number of doors locked by an interlocking controller, only one door opens at a time, Door Interlocking, while all other doors remain closed. This design minimizes microbiological and particulate contamination of the air-locked area, making our systems essential for maintaining a sterile environment. As top Air Shower Interlocking manufacturers in India, we prioritize quality and safety in all our products.

Air Shower Interlocking Suppliers in India

As prominent Air Shower Interlocking suppliers in India, Allsecure Enterprises offers a wide range of air shower interlocking systems. Our controllers are available in configurations of 2 and 3 doors, with both vertical and horizontal displays, and one-sided or all-sided blower operation. We are committed to providing exceptional service as Air Shower Interlocking suppliers in India, ensuring that our clients receive reliable solutions tailored to their specific needs.

Air Shower Interlocking Exporters in India

Allsecure Enterprises also serves as a trusted partner among Air Shower Interlocking exporters in India. We are dedicated to delivering our high-quality air shower interlocking systems to international markets while adhering to rigorous quality standards. Our reputation as reliable Air Shower Interlocking exporters in India stems from our commitment to innovation, safety, and customer satisfaction.

© ALLSECURE ENTERPRISES, All Right Reserved.
Designed and Developed By Highxbrand India Pvt. Ltd.